Timers and Clocks

TIMERS AND CLOCKS

  • Configured as a:
  • Timer – measures elapsed time between external events or controls external events.
  • Clock – displays local time and controls external equipment.
  • Robust enclosures including Stainless Steel panel mounting instrument.
  • Models:
    One and two input, externally powered
    Field and panel mounting
  • Certifications:
    -Intrinsically safe for Class I, Division 1, Groups A, B, C, D
    -Intrinsically safe for Class II, Division 1, Groups E, F, G
    -Intrinsically safe for Class III, Division 1
    -Intrinsically safe Ex ia for Zones 0, 1, 2, 20, 21, & 22
    -Rugged Stainless Steel Ex ia model may be installed in certified Ex e, Ex p or Ex t panel enclosure without invalidating the enclosure’s certification.
    -Non incendive Class I, Division 2, Groups A, B, C, D
    -Non incendive Class II, Division 2, Groups F, G
    -Non incendive Class III, Division 2
    -Ex nA & Ex tc for Zone 2 & 22 applications
    -General purpose for use in safe area
  • Accessories:
    -Backlight
    -Isolated dual control outputs
    -Pipe mounting kits
    -Rear IP66 Sealing Kit for Panel Mounting Models
    -Scale Card and Tag – preprinted at no charge if ordered with unit
  • Three year guarantee

These versatile instruments can be configured on-site as a Timer or as a Clock, or can be supplied configured to customer’s requirements for no additional charge. As a Timer they can measure and display the elapsed time between external events using sensors connected to one or two inputs.

Optional dual control outputs enable the instrument to control external devices such as opening a valve for a fixed time. Control cycles can be repeated continuously or a specified number of times.

When configured as a Clock the instruments display local time in twelve or twenty four hour format and can be externally synchronized. Optional control outputs enable two external devices to be turned on and off at pre-set times twice in each twenty four hour period.

Timers or Clocks, Intrinsically safe, field mounting and panel mounting

These versatile intrinsically safe Timer or Clocks can perform a host of timing and control functions such as sampling or dosing within a hazardous area. An easy to use state and event structure enables relatively complex timing functions to be easily configured. Timing operations may be started and stopped via the inputs, or from the front panel buttons. The instrument display shows progress of the operation and international certification permits worldwide installation.

An internally powered backlight is available as a factory fitted accessory.

Timer or Clocks can be supplied configured and fitted with a customer specified printed scale card showing the units of time for no additional charge. Specified tag or application information can also be printed onto the rear of the instrument. An optional Stainless Steel legend plate is also available which can be supplied laser engraved with customer specified tag and application information for field mount models.

Intrinsically Safe Panel Mounting
Model BA377E BA378E BA377E-SS
Image
Mouting Type Panel Panel Rugged Panel
Enclosure 96 x 48 mm 144 x 72 mm 105 x 60 mm
Separate terminal compartment N/A N/A N/A
Case material Noryl 316 Stainless Steel
Protection Front IP66, rear IP20
Display 8 digits 9mm high
6 digits 6mm high
8 digits 18mm high
6 digits 12mm high
8 digits 9mm high
6 digits 6mm high
No. of inputs 1 2 1
Certification
Europe
ATEX
Group II Category 1G
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C
Group II Category 1GD
Ex ia IIC T5 Ga
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
USA & Canada
ETL & cETL
Intrinsic safety
Class I Div 1 Gp A, B, C, D T5 (USA & Canada)
Class II Div 1 Gp E, F, G. Class III Div 1 (USA & Canada)
Class I Zone 0 AEx ia IIC T5 Ga (USA)
Ex ia IIC T5 Ga (Canada)
-40°C ≤ Ta ≤ 70°C
Zone 20 AEx ia IIIC
T80°C Da (USA)
Ex ia IIIC T80°C Da
(Canada)
-40°C ≤ Ta ≤ 60°C
May be installed in an
AEx e, AEx p, AEx n
or AEx t panel
enclosure without
invalidating enclosure
certification.
USA & Canada
ETL & cETL
Nonincendive
Class I Div 2 Gp A, B, C, D T5 (USA & Canada)
Class II Div 2 Gp F, G. Class III Div 2 (USA & Canada)
-40°C ≤ Ta ≤ 70°C
International
IECEx
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C Ex ia IIC T5 Ga
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
Optional
Backlight Yes
Control outputs Yes
Status output Not available Standard Not available

# Shown with optional separately powered backlight.

Intrinsically Safe Field Mounting
Model BA374E BA374G
Image
Mouting Type Field Field Compact
Enclosure 141 x 212 mm 122 x 120 mm
Separate terminal compartment Yes No
Case material Noryl
Protection IP66
Display 8 digits 18mm high
and 6 digits 12mm high
No. of inputs 2 2
Certification
Europe
ATEX
Group II Category 1G
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Group II Category 1GD
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
USA & Canada
ETL & cETL
Intrinsic safety
Class I Div 1 Gp A, B, C, D T5 (USA & Canada)
Class II Div 1 Gp E, F, G. Class III Div 1 (USA & Canada)
Class I Zone 0 AEx ia IIC T5 Ga (USA)
Ex ia IIC T5 Ga (Canada)
-40°C ≤ Ta ≤ 70°C
USA & Canada
ETL & cETL
Nonincendive
Class I Div 2 Gp A, B, C, D T5
Class II Div 2 Gp F, G. Class III Div 2
-40°C ≤ Ta ≤ 70°C
International
IECEx
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C
Optional
Backlight Included Yes
Control outputs Included Yes
Status output Standard

# Shown with optional separately powered backlight.

TIMERS AND CLOCKS, NON INCENDIVE AND EX NA, FIELD MOUNTING AND PANEL MOUNTING

This versatile non incendive, Ex nA and Ex tc certified Timer or Clock can perform a host of timing and control functions, such as sampling or dosing,
within a Class I, Division 2, Class II, Division 2, Groups F, G, Class III, Division 2, Zone 2 or Zone 22 hazardous areas without the need for
Zener barriers or galvanic isolators, thus significantly reducing cost. An easy to use state and event structure enables relatively complex timing functions
to be easily configured. Timing operations may be started and stopped via the inputs, or from the front panel buttons. The instrument display shows
progress of the operation and international certification permits worldwide installation.

An internally powered backlight is available as a factory fitted accessory.

The instrument can be supplied configured and fitted with a customer specified printed scale card showing the units of time for no additional charge.
Specified tag or application information can also be printed onto the rear of the instrument. An optional Stainless Steel legend plate is also
available which can be supplied laser engraved with customer specified tag and application information for field mount models.

Non-Incendive Field Mounting Non-Incendive Panel Mounting
Model BA374NG BA377NE
Image
Mouting Type Field Compact Rugged Panel
Enclosure 122 x 120 mm 105 x 60 mm
Separate terminal compartment N/A N/A
Case material GRP 316 Stainless Steel
Protection IP66 Front IP66, rear IP20
Display 8 digits 18mm high
and 6 digits 12mm high
8 digits 9mm high
and 6 digits 6mm high
No. of inputs 2 1
Certification Ex ic certification codes only refer to the instrument push button contacts which are non-incendive.
Europe
ATEX
Group II Category 3GD
Ex nA ic IIC T5 Gc
Ex ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ +60°C
USA ETL Class I Zone 2 AEx nA ic IIC T5 Gc
Zone 22 AEx ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ 60°C
Canada cETL Ex nA ic IIC T5 Gc
Ex n IIC T5 Gc
Ex ic tc IIIC T80°C Dc
Class III Div 2 Class II Div 2
Gp F, G
-40°C ≤ Ta ≤ 60°C
Ex nA ic IIC T5 Gc
Ex n IIC T5 Gc
-40°C ≤ Ta ≤ 60°C
USA & Canada
ETL & cETL
Nonincendive
Class I, Division 2, Groups A,B,C,D Class II, Division 2, Groups F, G Class III, Division 2
International
IECEx
Ex nA ic IIC T5 Gc
Ex ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ +60°C
Optional
Backlight Yes
Control outputs Yes
Status output Included N/A

# Shown with optional separately powered backlight.

TIMERS AND CLOCKS, GENERAL PURPOSE, FIELD MOUNTING AND PANEL MOUNTING

This versatile general purpose instrument can perform a host of timing and control functions such as sampling or dosing within a process area. An easy
to use state and event structure enables relatively complex timing functions to be easily configured. Timing operations may be started and stopped via
the inputs, or from the front panel buttons. The instrument display shows progress of the operation.

An internally powered backlight is available as a factory fitted accessory.

Timers or Clocks can be supplied configured and fitted with a customer specified printed scale card showing the units of time for no additional charge.
Specified tag or application information can also be printed onto the rear of the instrument. An optional Stainless Steel legend plate is also
available which can be supplied laser engraved with customer specified tag and application information for field mount models.

General Purpose Field Mounting General Purpose Panel Mounting General Purpose Panel Mounting General Purpose Rugged Panel Mounting
Model BA574G BA577E BA578E BA577E-SS
Image
Mouting Type Field Compact Panel Panel Rugged Panel
Enclosure 122 x 120 mm 96 x 48 mm 144 x 72 mm 105 x 60 mm
Separate terminal compartment N/A
Case material GRP Noryl 316 Stainless Steel
Protection IP66 Front IP66, rear IP20
Display 8 digits 18mm high
and 6 digits 12mm high
8 digits 9mm high
6 digits 6mm high
8 digits 18mm high
6 digits 12mm high
8 digits 9mm high
6 digits 6mm high
No. of inputs 2 1 2 1
Certification
Europe
ATEX
N/A
USA ETL N/A
Canada cETL N/A
USA & Canada
ETL & cETL
Nonincendive
N/A
International
IECEx
N/A
Optional
Backlight Yes
Control outputs Yes
Status output Standard Not available Standard Not available

# Shown with optional separately powered backlight.

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT

Download Product and Service Catalogs

Fill out your contact details and we will forward you to download our product brochures. 

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT