Purge Solutions CYCLOPS X – Purge Controller XP

SKU Cyclops X Category

GET A QUOTE – Not available for purchase online. Please click the link to request a quote or call 281-978-2040.

The CYCLOPS X – Purge Controller is certified for use in Division 1 and / or Zone 1 hazardous areas, which monitors purge pressure, exhaust vent flow, and controls electrical power and pre dilution purge time of one (1) pressurized enclosure.

Purge gas inlet kits are available with each controller. Contact us at 281-978-2040 for further details.

 

 

 

 

We are an authorized Purge Solutions distributor shipping worldwide.

Connect with Hazardous Area Expert

Questions
or Volume Pricing?

Connect with Hazardous Area Expert:
281-978-2040 | Chat with Us
Get Quote

Description

  • Simple to install & use
  • Highly reliable
  • Enclosure purge exhaust vent is part of casing
  • Local & remote status alarms
  • Casing available in anodized aluminum or 316 stainless-steel
  • 115 VAC, up to 25 Amps or 230 VAC, up to 12.5 Amps
  • All in One Unit

The CYCLOPS X – Purge Controller provides local and remote objective evidence of the presence of positive purge pressure within the electrical equipment enclosure and enclosure’s exhaust port flow. When the monitored enclosure registers a pressure of at least 0.30 inches of water column (0.75mbar) above the referenced atmospheric pressure surrounding the enclosure being monitored and the exhaust port is registering satisfactory flow, CYCLOPS’s local green LED indicator will begin flashing. An automatic dilution purge controlled time delay may then begin. The time delay can be set from one (1) to ninety nine (99) minutes, which is set by the customer to allow at least five (5) times the volume of free space in the enclosure to be exchanged before power is automatically applied by the CYCLOPS X – Purge Controller to the electronic equipment within the enclosure the CYCLOPS is monitoring.

After the automatic dilution purge time has elapsed, the local green LED indicator will stop flashing and go into a continuous green state. Indicating that the monitored enclosure pressure is being maintained above 0.30 inches of water column (0.75mbar) and enclosure exhaust port is registering satisfactory flow. Up to 12.5 Amps of power will then be automatically applied by the CYCLOPS X – Purge Controller, eliminating the need for an additional explosion proof enclosure with a solid-state relay.

The CYCLOPS X – Purge Controller continuously compares the purge pressure inside the monitored electrical equipment enclosure with respect to the atmospheric pressure surrounding the enclosure preventing the ingress of flammable materials in the surrounding atmosphere from entering into the enclosure as long as positive purge pressure and exhaust port flow is maintained. If the enclosure pressure should go below 0.30 inches of water column (0.75mbar) and / or exhaust port flow stops the local LED indicator will go from steady state of green to a steady state of red, power will be disconnected from the unprotected monitored electrical equipment and if used a dry-contact alarm for either situation, will be sent to the remote point for monitoring.

Other features of the CYCLOPS X – Purge Controller are a Maintenance Switch and Power Disconnect Bypass Switch. The Maintenance Switch is used when electrical equipment within the enclosure being monitored by the CYCLOPS X – Purge Controller requires electrical power for repair or maintenance. After the area surrounding the enclosure has been tested and is known to be non-hazardous. The enclosure can then be opened without protective purge pressure exposing the electronic equipment to its surrounding atmosphere. The CYCLOPS X – Purge Controller’s Maintenance Switch can then be put in maintenance mode and power will then be applied to the electrical equipment for repair or maintenance. During this time the local visual LED indicator will flash red and if used, the dry contact will send an alarm to its point of remote monitoring. When repair or maintenance has been completed. The electronics equipment’s enclosure door can then be closed and fastened. Purge pressure can then be restored to the enclosure and if the purge pressure remains above 0.30 inches of water column (0.75mbar) and if there is satisfactory exhaust vent flow, the Maintenance Switch when turned to normal operation, instead of going through the dilution cycle, the electrical equipment’s power will remain on.

The Power Disconnect Bypass Switch is used to override the disconnecting of power to the electrical equipment within the enclosure being monitored by the CYCLOPS X – Purge Controller for installations where immediate loss of power would result in a more hazardous condition. Power to the electrical equipment within the enclosure being monitored by the CYCLOPS X – Purge Controller shall be permitted to be continued for a short period of time if both audible and visual alarms are provided at a constantly attended location. During this time the local visual LED will be a steady state green and blink red.

The enclosure exhaust vent is an integrated part of the CYCLOPS’s casing. The CYCLOPS X – Purge Controller mounts directly to the enclosure being purged. This means no additional holes, sheet metal, or plumbing is required for installation of the CYCLOPS X – Purge Controller. The CYCLOPS X – Purge Controller comes in anodized aluminum or 316 stainless-steel, with voltage options of 115 or 230 VAC able to control up to 12.5 Amps.

Technical Data

Overall Unit Dimensions 8.0” diameter x 1.9” tall (203.2mm diameter x 48.3mm tall); protrudes outside of enclosure.
6.5” diameter x 4.50” tall (165.1mm diameter x 114.0mm tall); protrudes inside of enclosure.
Unit Weight CYCLOPS X – Purge Controller, XP Version, Anodized Aluminum = 16.9 lbs. (7.30 kg)
CYCLOPS X – Purge Controller, XP Version, 316 Stainless Steel = 37.98 lbs. (17.23 kg
Operating Temperature Range CYCLOPS X – Purge Controller, XP Version, Anodized Aluminum = 16.9 lbs. (7.30 kg)
CYCLOPS X – Purge Controller, XP Version, 316 Stainless Steel = 37.98 lbs. (17.23 kg)
Minimum Overpressure Switch Settings 0.30 inch H2O (0.75 mbar) for gas hazardous locations
0.50 inch H2O (1.25 mbar) for dust hazardous locations
Power Input / Consumption 2 watts max
Ingress Protection Anodized Aluminum and 316 Stainless Steel = NEMA 4X (IP66)
Voltage 115 VAC model (85 VAC to 160 VAC), 47 to 63 Hz.
230 VAC model (130 VAC to 265 VAC), 47 to 63 Hz.
Alarm Dry Contact Maximum Continuous Load Rating Contact open on alarm (NO)
Contact closed on alarm (NC)
150 mA rms AC
150 mA DC
Standard Hardware Stainless steel mounting hardware, O-ring and USB with unit documentation.

Resources

CYCLOPS – X Purge Controller XP User Manual
CYCLOPS – Z Purge Controller XP Brochure
ATEX Certificate
IECEX Certificate
NEC/NFPA Certificate
CEC Certificate
EU Declaration of Conformity

Approvals



 

 

ATEX and IECEx
II 2 G Ex e mb ib [px] IIC T4 Gb for Zone 1 gas hazardous areas
II 2 D Ex tb IIIC T119°C Db IP66 for Zone 21 dust hazardous areas
ANSI / ISA 12.4, CEC, NEC and NFPA 496
Class I, Division 1, Group B,C,&D, T4 for gas hazardous areas
Class II, Division 1, Group E,F&G, T4 for dust hazardous areas
Certified to an Ambient Temperature Range of – 40ºF (- 40ºC) <Tamb< + 149ºF (+ 65ºC)
CE Marked