Hazardgard Air Conditioners

HAZARDGARD AIR CONDITIONERS

PROVEN HIGH PERFORMANCE AIR CONDITIONING IN THE MOST CHALLENGING ENVIRONMENTS

  • ATEX and IECEX Zone 2 certified ExnA nC IIC T4 Gc
  • UL Listed for Class 1 Division 2, Groups A,B,C,D
  • Environmentally sealed on/off switch and gold plated contacts in thermostat for corrosion resistance
  • Hermetically sealed refrigeration system
  • Durable outdoor industrial electrical cable harnesses and cable glands
  • 19500 up to 24000 Btu/Hr Cooling capacity 

For more than three decades, global industry and high-tech leaders have trusted Friedrich to provide commercial-grade cooling under the harshest conditions. You’ll find durable, reliable Hazardgard room air conditioners on oil rigs and military bases, in manufacturing companies and processing plants – anywhere hazardous materials are used. Hazardgard is specifically designed to cool spaces where volatile, flammable liquids and gases are used, within enclosed systems or containers, or under extreme temperatures.

ROOM SIZING GUIDE

FT2 BTU
100–150 5000
150-250 6000
250-300 7000
300–350 8000
350–400 9000
400–450 10000
450-550 12000
550-700 15000
700–1000 18000
1000-1200 21000
1200-1400 23000
1400–1600 25000
1600–1900 28000
1900–2700 36000

TEMPERATURE CLASSIFICATION

Electrical equipment, like hazardous location air conditioners, that may be exposed to specific, hazardous gases or vapors in the area where it will be used, cannot reach temperatures that exceed 80% of the auto-ignition temperature of those gases or vapors. The Hazardgard air conditioners have a T4 rating which means their surface temperature should not exceed 135°C or 275°F. (Note: 50/60Hz model listed as T4A for surface temperatures to 120° C/248° F).

Electrical Equipment Label Temperature (C) Temperature (F)
T1 450°C 842°F
T2 300°C 572°F
T2A 280°C 536°F
T2B 260°C 500°F
T2C 230°C 446°F
T2D 251°C 483.8°F
T3 200°C 392°F
T3A 180°C 356°F
T3B 165°C 329°F
T3C 160°C 320°F
T4 135°C 275°F
T4A 120°C 248°F
T5 100°C 212°F
T6 85°C 185°F

The above chart illustrates that 200°C is the maximum surface temperature for any electrical equipment with a temperature classification of T3 or higher.

SPECIFICATIONS

Model Cooling Capacity (Btu/Hr.) Volts Rated Cooling Amps Cooling Watts Energy Efficiency Ratio Moisture Removal Pints/HR Air Direction Controls Air Circulation (CFM) Refrigerant
60 H E R T Z – P E R F O R M A N C E
SH24N20AT 2400/23700 230/208/60 12.6/13.5 2727/2788 8.8/8.5 8.20/7.5 8-way 385 R-410A
50 H E R T Z – P E R F O R M A N C E
SH24N20AT 21000/20500 240/220-50 15.0/13.2 2600/2412 8.1/8.5 7 8-way 360 R-410A
SH20N50AT 19500/19100 240-220-50 9.8/10.3 2167/2156 9.0/9.0 5.6/5.5 8-way 425 R-410A

INSTALLATION INFORMATION

Unit Dimensions Window Width In-Wall Installation Finished Hole Circuit Rating Breaker or T-D Fuse Weight lbs
Model Height Width Depth with Front A Depth J Box to Louvers B Minimum Extensions Into Room Minimum Extension Outside Min Max Height Width Max Depth Volts-Amps Net Shipping
SH24N20AT 17 15/16″ 25 15/16″ 27 3/8″ 6″ 3 1/16″ 16 15/16″ 27 7/8″ 42″ 18 3/16″ 26 3/16″ 6″ 250V-30 180 185
SH20N50AT 17 15/16″ 25 15/16″ 27 3/8″ 6″ 3 1/16″ 16 15/16″ 27 7/8″ 42″ 18 3/16″ 26 3/16″ 6:00 250V-15 171 175

Due to continuing engineering research and technology, specifications are supbject to change wihtout notice. Manufactured under U.S. Design Patent DES 368, 306 decorative front; Utility Patent 5, 662, 058. MAXIMUM outdoor ambient operating temperature is 130ºF. (55ºC) MAXIMUM TEMPERATURE RATING FOR CLASS 1, DIVISION 2, GROUPS A, B, C, D. Capacity and efficiency values at each climate conditions are available upon request. NOTE: Hazardgard unit must be hard-wired.