The iUPS Series provide reliable UPS under extreme conditions including hazardous (classified) locations typically found in chemical plants, oil refineries, and around oil & gas platforms. Critical equipment such as servers, process analysers, and control systems can be protected in the event of a brown out or other supply disturbance.

In Zone 1 the iUPS101 can provide 120 or 230 VAC at 3 kVA for 35 minutes and has alarm and status LEDs visible through a glass window. Surface mounted switches provide input / output power isolation, and a stainless steel close-coupled termination enclosure and external battery box means that the main explosion proof enclosure does not need to be opened. A second battery box can be added to double the run time. An upgraded version of the original iUPS100.

For Zone 2 the iUPS200 provides 12 or 24VDC at 70W for 120 minutes. The stainless steel enclosure may be wall or pole mounted and also accommodates the battery. Optional features include a choice of built-in status indication and pushbutton control, or active logic outputs for monitoring by a DCS or other control system.

Both models include advanced battery charging technology including temperature compensation to maximize battery life and performance.

Choice by Zone iUPS101 for Zone 1 iUPS200 for Zone 2
Certification ATEX II 2 G Ex d[e] e IIB T5 Gb IECEX now available ATEX II 3 G Ex nA II T4 (-20°C≤Ta≤+55°C)
Input Power 230V iUPS101: 180-265VAC (45-65Hz)
120V iUPS101: 90-150VAC (55-75Hz)
90-264VAC
Output Power 230VAC or 120VAC ±2% 50/60 Hz
at up to 3KVA (de-rated by ambient temp)
67.2W, 5.6A at 12VDC, or 62.4W, 2.6A at 24VDC
depending on battery/power output voltage ordered
Backup Time Approx. 39 minutes at 68°F/20°C, full load, or 87 minutes with additional battery enclosure.
See data sheet for run time table.
Approx. 120 minutes at 77°F/25°C, full load
Alarm Output Programmable volt-free contacts Optional logic signals
Environmental Protection Main Ex d enclosure: IP66, aluminum alloy
Termination Ex e enclosure: IP66, stainless steel
Battery Ex e enclosure: IP23, stainless steel
IP66, 316L stainless steel
Operating Temperature -4°F to +131°F / -20°C to +55°C @ 500VA
See data sheet for de-rating table.
-4°F to +131°F / -20°C to +55°C
Weight Main enclosure + Terminal enclosure: 198lb / 90Kg
Battery enclosure: 269lb / 122Kg
Approx: 33lb / 15Kg

IBATT100 ZONE 1 STAINLESS STEEL BATTERY ENCLOSURE

Part of the iUPS101 system, but available separately for applications requiring 24VDC power in Zone 1 and 2 hazardous areas. Ideal for use on oil and gas platforms, refineries, wellheads, and pipeline facilities.

Includes two 12V vent regulated lead acid batteries connected in series. These advanced technology batteries are maintenance free and provide superior performance and cycle life compared to conventional electrolyte batteries. Charging in a hazardous location is permissible by compliance with the ATEX certificate and requirements of EN60079-0 and EN60079-7.

The wall mounting 316L stainless steel enclosure includes a lockable hinged door for easy access and battery replacement. The iBATT100 is supplied with the battery link cable and battery terminal insulating boots.

IBATT5XX ZONE 1&2 STAINLESS STEEL UNIVERSAL BATTERY ENCLOSURE

The iBATT5xx is designed to be configured to suit your application. It is available in a wide range of sizes and will contain the batteries of your choice.

  • ATEX/IECEx Zone 1 and Zone 2 certified
  • Stainless steel
  • Can be used to deploy various battery types in hazardous areas
  • Scalable solution, tailored to your application
  • II 2G Ex e IIC T6 Gb
  • -40°C to +55°C
  • IP43 (Ex rating), IP66 (on request)
Extronics iBATT5xx Zone 1 and 2 Stainless-Steel Universal Battery Enclosure
Universal enclosure system

The iBATT5xx is designed to house a variety of different lead acid, nickel cadmium, and nickel iron batteries.

Flexible charging

As well as safe area charging, the iBATT5xx may be charged in the hazardous area in line with the battery manufacturer’s instructions, providing that a method of protecting against overvoltage and overcurrent is used.

Tailored to your application

Scalable to suit the installation requirements, the iBATT5xx is available in a number of sizes and can incorporate up to 36 battery cells.

Tailored Use standalone or as part of a UPSto your application

The iBATT5xx can be used as an independent battery enclosure, providing the special conditions for safe use (as per the ATEX/IECEx certificates) are met. The iBATT5xx can also be easily used in conjunction with Extronics’ range of UPS solutions, such as the iUPS101.

BKEX ZONE 1/21 BATTERY BOX

The BK-Ex is a rugged stainless steel rechargeable battery enclosure for use in the hazardous area. The enclosure can be used in mobile or fixed applications and is fitted with an ATEX certified outlet socket for easy connection to the equipment. The enclosure cannot be recharged in the hazardous area.

  • ATEX Zone 1 and 21 certified
  • Provides battery power in hazardous areas
  • Highly durable and rugged
  • II 2G EEx ed IIC T6
  • II 2D T80ºC
  • IP65
Provide battery power in hazardous areas

The BK-EX is a rechargeable battery enclosure than can be used in mobile or fixed applications.

Easy connection

With an ATEX certified outlet socket, the BK-EX is easy to connect to equipment.

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT

Download Product and Service Catalogs

Fill out your contact details and we will forward you to download our product brochures. 

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT