BEKA Serial Operator Interface Displays

BEKA SERIAL DATA DISPLAYS USED AS AN OPERATOR INTERFACE

FEATURES:

  • Displays text and simple graphics
  • High contrast display with back light
  • Incorporates operator push buttons
  • Modbus, legacy & BEKA protocol
  • RS232 and RS485 ports
  • 11 standard screens with up to 8 variables on each
  • 2 solid state outputs
  • Galvanic isolator for hazardous area applications
  • Models for:
    Intrinsically safe Ex i applications
    General purpose applications
    Field and panel mounting
  • Accessories:
    Pipe mounting kits
  • Three year guarantee

These Serial Text displays incorporate a high contrast backlit display, push buttons and two solid state outputs, to form a low cost operator interface which is ideal for simple process and machine control applications.

The text displays support Modbus, BEKA and legacy protocols and include eleven standard screen formats that can display up to eight variables on each screen, some with bargraphs. If custom display formats are required, these can be constructed using the free BEKA ScreenWriter software.

The intrinsically safe models communicate and are powered via a 2 or 3 wire system from a galvanic isolator in the safe area. To simplify hazardous area installations, the BA201 certified galvanic isolator which has RS232 and RS485 safe area ports can power up to four BEKA intrinsically safe Serial Text Displays.

The general purpose models are separately powered and have RS232 and RS485 ports.

For more information, please choose the model which best suits your application from the table below.

Intrinsically Safe, Field Mounting
Model BA484D
Style
Mounting Field
Protection IP66
Display High contrast 86.5mm x 45mm
with backlight, up to 8 variables
Communications Interface via BA201 (other isolators may be used) RS232 or RS485
Protocol Modbus, BEKA & Legacy
Operator push buttons 4
Connections for remote operator push buttons 6
Solid state outputs 2
Certification
Europe ATEX ATEX Group II Category 1G
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +60°C
International IECEx Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +60°C
Optional
USA FM certification 3610 Entity CL I, II, III Div. 1
Gp A, B, C, D, E, F & G T4 Ta = +60°C
3611 Nonincendive CL I, II, III Div. 2
Gp A, B, C, D, E, F & G T4 Ta = +60°C
Canada cFM certification Entity CL I, II, III Div. 1
Gp A, B, C, D, E, F & G T4 Ta = +60°C
IPA CL I, II, III Div. 2
Gp A, B, C, D, E, F & G T4 Ta = +60°C
Europe ATEX Dust certification Group II Category 1D
Ex ia IIIC T80°C IP66 Da
-40°C ≤ Ta ≤ +60°C
International IECEx Dust certification Ex ia IIIC T80°C IP66 Da
-40°C ≤ Ta ≤ +60°C

Datasheet

ATEX Certificate

FM Certificate

cFM Certificate

IECEx Certificate

Ingress Protection

Instruction Manual

Modbus Interface

Guide
Programming

Guide
Declaration of Conformity

Get a Quote

Intrinsically Safe, Panel Mounting
Model BA488C
Style
Mounting Panel
Protection Front IP66, rear IP20
Display High contrast 86.5mm x 45mm
with backlight, up to 8 variables
Communications Interface via BA201 (other isolators may be used) RS232 or RS485
Protocol Modbus, BEKA & Legacy
Operator push buttons 6
Connections for remote operator push buttons 6
Solid state outputs 2
Certification
Europe ATEX ATEX Group II Category 1G
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +60°C
USA FM 3610 Entity CL I Div. 1
Gp A, B, C & D T4 Ta = +60°C
3611 Nonincendive CL I Div. 2
Gp A, B, C & D T4 Ta = +60°C
Canada cFM Entity CL I Div. 1
Gp A, B, C & D T4 Ta = +60°C
IPA CL I Div. 2
Gp A, B, C & D T4 Ta = +60°C
International IECEx Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +60

Datasheet

ATEX Certificate

FM Certificate

cFM Certificate

IECEx Certificate

Ingress Protection

Instruction Manual

Modbus Interface

Guide
Programming

Guide
Declaration of Conformity

Get a Quote

General Purpose, Field Mounting
Model BA684D
Style
Mounting Panel
Protection IP66
Display High contrast 86.5mm x 45mm with backlight, up to 8 variables
Communications Interface RS232 or RS485
Protocol Modbus, BEKA & Legacy
Operator push buttons 6
Connections for remote operator push buttons 6
Solid state outputs 2

Datasheet

Ingress Protection

Instruction Manual

Modbus Interface Guide

Programming Guide

Declaration of Conformity
Get a Quote

General Purpose, Field Mounting
Model BA688C
Style
Mounting Panel
Protection Front IP66, rear IP20
Display High contrast 86.5mm x 45mm with backlight up to 8 variable
Communications Interface RS232 or RS485
Protocol Modbus, BEKA & Legacy
Operator push buttons 6
Connections for remote operator push buttons 6
Solid state outputs 2

Datasheet

Ingress Protection

Instruction Manual

Modbus Interface Guide

Programming Guide

Declaration of Conformity

Get a Quote

Communications Isolator
Model BA201
Style
Mounting 35mm DIN rail
Protection IP20
Certification
Europe ATEX ATEX Group II Category (1) G
[Ex ia] IIC Tamb = -40°C to +60°C
USA FM Entity AIS CL I, II, II
Gp A, B, C, D, E, F & G
Non incendive CL I Div 2
Gp A, B, C & D T5 Ta = +60°
Canada cFM Entity AIS CL I, II, II
Gp A, B, C, D, E, F & G
Non incendive CL I Div 2
Gp A, B, C & D T5 Ta = +60°
International IECEx 6[Ex ia] IIC Tamb = -40°C to +60°C

Datasheet

ATEX Certificate

FM Certificate

cFM Certificate

IECEx Certificate

Instruction Manual

Declaration of Conformity

Get a Quote

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT

Download Product and Service Catalogs

Fill out your contact details and we will forward you to download our product brochures. 

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT