Exloc Instruments Logo
Search
Close this search box.

BEKA Rugged Indicators for Process Control

BEKA 4-20MA RUGGED PANEL MOUNTED LOOP POWERED INDICATORS

Provide Process Information in Hazardous Locations & Extreme Environments

  • Rugged stainless steel panel mounting models:
    • Type nA versions for use in Ex n, Ex e, Ex p and Ex t panel enclosures in Zones 2 & 22 – Ex nA & Ex tc certification eliminates the need for Zener barriers and galvanic isolators
    • Intrinsically safe versions for use in Ex e, Ex p and Ex t panel enclosures in Zones 1, 2, 21 & 22
    • General purpose versions also available
  • Large, non-multiplexed digital displays
  • Full 4 & 5 digit readout, plus bargraph on selected models
  • High contrast and wide angle viewing
  • -40°F to +158°F / -40°C to +70°C operating temperature
  • cFM, FM, ATEX and IECEx certification, for hazloc applications
  • IP66 ingress protection
  • Optional backlighting and alarm outputs
  • Internal calibration source
  • Root extractor and lineariser
  • Tare function
  • Three year guarantee
Exloc Instruments

BEKA’s fourth generation ‘E’ Series loop powered 4-20mA indicators include models for field and panel mounting in both safe and hazardous locations. The models shown on this page are the new rugged versions housed within robust stainless steel cases designed to be panel mounted in both hazloc and general purpose applications.

The BA307E-SS and BA327E-SS fourth generation intrinsically safe 4/20mA loop powered indicators have large high contrast displays with a very wide viewing angle. Operating over an extended temperature range they contain many standard features previously only available as options. Coated printed circuit boards plus extensive thermal and vibration testing provides maximum reliability supported by a three year guarantee.

BA307NE and BA327NE loop powered indicators have third party Ex nA and Ex tc certification allowing them to be installed in an Ex n, Ex e, Ex p or Ex t enclosure located in Zone 2 or 22 without the need for a barrier or galvanic isolator.

All BEKA indicators are calibrated to customer requirements free of charge and can be labeled to show units of measurement, tag number, and application.

Display Readability/Formatting
No backlight – Display readable in daylight
Backlight, loop powered – Display readable in poor lighting conditions. indicators
Backlight, separately powered – Display contrast enhanced in all lighting conditions
Maximum display for 4-digit indicators
Maximum display for 5-digit indicators

Duty / Service Hazloc, Intrinsically Safe, Rugged, Panel Mounting Hazloc, Intrinsically Safe, Rugged, Large Panel Mounting
Model No. BA307E-SS BA327E-SS BA304G-SS-PM BA324G-SS-PM
Style
Display Format 4 digits, 15mm high 5 digits, 11mm high, plus bargraph 4 digits, 34mm high 5 digits, 29mm high, plus bargraph
Ingress Protection Front IP66, rear IP20 Front IP66, rear IP20
USA FM & Canada cFM Entity IS / I / A, B, C, D / T5
Ta = 70°C
I / 0 / AEx ia IIC / T5 Ta = 70°C
May be installed in AEx e, AEx p or AEx t panel enclosure without invalidating enclosure certification
Not Applicable to North America
Europe, ATEX Gas: Group II, Category 1G, Ex ia IIC T5 Ga, -40°C ≤ Ta +70°C
Dust: Group II, Category 1D, Ex ia IIIC T80°C Da IP66, -40°C ≤ Ta +70°C< br> May be installed in Ex e, Ex p or Ex t panel enclosure without invalidating enclosure certification
Gas: Group II, Category 1G, Ex ia IIC T5 Ga, -40°C ≤ Ta +70°C
Dust: Group II, Category 1D, Ex ia IIIC T80°C Da IP66, -40°C ≤ Ta +70°C
May be installed in Ex e, Ex p or Ex t panel enclosure without invalidating enclosure certification
Other Regions, IECEx Gas: Ex ia IIC T5 Ga, -40°C ≤ Ta +70°C
Dust: Ex ia IIIC T80°C Da IP66, -40°C ≤ Ta +70°C
May be installed in Ex e, Ex p or Ex t panel enclosure without invalidating enclosure certification
Gas: Ex ia IIC T5 Ga, -40°C ≤ Ta +70°C
Dust: Ex ia IIIC T80°C Da IP66, -40°C ≤ Ta +70°C
May be installed in Ex e, Ex p or Ex t panel enclosure without invalidating enclosure certification
Alarms Available Available
Backlighting Available, loop powered or separately powered Available, loop powered or separately powered
Escutcheon scale & tag labeling Available Available

Datasheet

Manual

ATEX cert

IECEx cert

Get Help/Quotation

Datasheet

Manual

ATEX cert

IECEx cert

Get Help/Quotation

Datasheet

Manual

ATEX cert

IECEx cert

Ingress cert

Application guide AG300

Get Help/Quotation

Datasheet

Manual

ATEX cert

IECEx cert

Ingress cert

Application guide AG300

Get Help/Quotation

Duty / Service Hazloc, Type nA, Rugged, Panel Mounting
Model No. BA307NE BA327NE
Style
Display Format 4 digits, 15mm high 5 digits, 11mm high, plus bargraph
Ingress Protection IP66 Front, rear IP20 IP66 Front, rear IP20
USA ETL & Canada cETL Class I, Zone 2, AEx nA ic IIC T5 Gc
Zone 22, AEx ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ 60°C
Ex nA ic IIC T5 Gc: Ex n IIC T5 Gc
Ex ic tc IIIC T80°C Dc
-40°C ≤ Ta ≤ 60°C
Europe ATEX Gas – Group II Category 3G Ex nA ic IIC T5 Gc -40°C ≤ Ta ≤ +70°C
Dust – Group II Category 3D Ex tc IIIC T80°C Dc IP20 -40°C ≤ Ta ≤ +70°C
IECEX Gas – Ex nA ic IIC T5 Gc -40°C ≤ Ta ≤ +70°C
Dust – Ex tc IIIC T80°C Dc IP20 -40°C ≤ Ta ≤ +70°C
Alarms Yes
Backlighting Yes
Escutcheon scale & tag labeling Yes

Datasheet

ATEX cert

IECEX cert

ETL certs

Ingress cert

Application guide AG310
Manual

Get Help/Quotation

Datasheet

ATEX cert

IECEX cert

ETL certs

Ingress cert

Application guides AG310
Manual

Get Help/Quotation

Duty / Service General Purpose, Panel Mounting
Model No. BA507E-SS BA527E-SS
Style
Front Face DIN Size 105 x 60 mm 105 x 60 mm
Display Format 4 digits, 15mm high 5 digits, 11mm high, plus bargraph
Ingress Protection Front IP66, rear IP20
Alarms Available
Backlighting Available, loop powered or separately powered
Scalecard and tag / application marking (no charge) Available

RUGGED STAINLESS STEEL 4/20MA LOOP POWERED INDICATORS, FIELD MOUNTING

Provide Process Information in Hazardous Locations & Extreme Environments

  • Rugged stainless steel field mounting models
  • ATEX, IECEx, USA & Canadian intrinsically safe and general purpose models
  • Large, non-multiplexed digital displays
  • Full 4 & 5 digit readout, plus bargraph on selected models
  • -40°F to +158°F / -40°C to +70°C operating temperature
  • IP66 ingress protection
  • Optional backlighting and alarm outputs
  • Internal calibration source
  • Root extractor and lineariser
  • Tare function
  • Three year guarantee
Exloc Instruments

Download logoProduct downloads

  • Display options
  • Product dimensions
  • Application guide AG300

These fourth generation intrinsically safe 4/20mA loop powered indicators have large high contrast displays with a very wide viewing angle. Operating over an extended temperature range they contain many standard features previously only available as options. Extensive thermal and vibration testing provides maximum reliability supported by a three year guarantee.

No additional charge is made for factory calibration or for scale and tag marking, although the indicators can easily be re-calibrated on-site.

To select the model and options for your application please refer to the following table.

Duty / Service Hazloc, Intrinsically Safe, Rugged, Field Mounting General Purpose, Rugged, Field Mounting
Model No. BA304G-SS BA324G-SS BA504G-SS BA524G-SS
Style
Display Format 4 digits, 34mm high 5 digits, 29mm high, plus bar graph 4 digits, 34mm high 5 digits, 29mm high, plus bar graph
Ingress IP66 IP66
USA ETL & Canada cETL Class I, Div 1, Gp A, B, C, D T5 (USA & Canada)
Class I, Zone 0, AEx ia IIC T5 Ga (USA)
-40°C ≤ Ta ≤ 70°C
Class II, Div 1, Gp E, F, G. Class III, Div 1 (USA & Canada)
Zone 20 AEx ia IIIC T80°C Da (USA)
-40°C ≤ Ta ≤ 60°C
Ex ia T5 Ga -40°C ≤Ta ≤ 70°C (Canada)
Ex ia IIIC Da -40°C ≤ Ta ≤ 60°C (Canada)
Not Applicable
Europe, ATEX Group II Category 1G
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C
Group II Category 1D Ex ia IIIC T80°C Da IP66
-40°C ≤ Ta ≤ +70°C
Not Applicable
IECEx Ex ia IIC T5 Ga
-40°C ≤ Ta ≤ +70°C
Ex ia IIIC T80°C Da IP66
-40°C ≤ Ta ≤ +70°C
Not Applicable
Alarms Yes Yes
Backlighting Available, loop powered or separately powered Available, loop powered or separately powered
Scale & tag labeling Yes Slide-in Yes Slide-in

Datasheet

Manual

ETL & cETL certs

ATEX cert

IECEx cert

Ingress cert

Get Help/Quotation

Datasheet

Manual

ETL & cETL certs

ATEX cert

IECEx cert

Ingress cert

Get Help/Quotation

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT

Download Product and Service Catalogs

Fill out your contact details and we will forward you to download our product brochures. 

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT