E2xB05 Specifications | ||
Available Models | E2xB05-UL | E2xB05-EG |
Certification |
UL Approved, US & Canada Cl I, Div 2, Grp A-D T2D @ +55°C Cl I, Div 2, Grp A-D T3 @ +40°C Cl II, Div 2, Grp F&G T5 @ +55°C Cl II, Div 2, Grp F&G T6 @ +40°C Cl III, Div 1, T5 @ +55°C Cl III, Div 1, T6 @ +40°C File No. E254313 |
ATEX certified Ex II 3G EEx nA nL IIC T2 (Tamb -20 to +55°C) Ex II 3G EEx nA nL IIC T3 (Tamb -20 to +40°C) Cert: DEMKO 06 ATEX 0421554 |
Light Source |
Xenon, 5 Joule @ 1Hz (5 Ws), user replaceable. Xenon tube mechanically secured against vibration/shock. Lens colors: red, amber/orange, blue, green, yellow, clear. |
|
Power Supply Options |
12VDC (10-14V) @ 520mA 24VDC (20-28V) @ 275mA 48VDC (42-58V) @ 145mA 120VAC ±10% 50-60Hz @ 80mA 230VAC ±10% 50-60Hz @ 30mA |
|
Operating Temperature | -4 to +131°F / -20 to +55°C | |
Materials |
Body: UL94V0 & ABS; Mounting bracket: stainless steel; Glass dome: borosilicate; Glass dome guard: stainless steel |
|
Environmental Protection | NEMA TYPE 4 / 4X / 13 | IP 66 / IP67 |
Cable Entry | One ½”NPT | Two M20 |
Terminations | 18″ / 0.5m flying leads | Terminals for 0.5 to 2.5mm² wire |
Weight | 3.26lb / 1.48Kg | |
Other | UL Approval includes for end-of-line resistor on DC-powered versions (see instruction manual) | ATEX certification includes for in/out wiring (see instruction manual) |
E2B05-UL installation instructions
E2B05-UL UL certificate of compliance
E2xB10 Specifications | ||
Available Models | E2xB10-UL | E2xB10-EG |
Certification |
UL Approved, US & Canada Cl I, Div 2, Grp A-D T2A @ +55°C Cl II, Div 2, Grp F&G T4A @ +55°C Cl II, Div 2, Grp F&G T5 @ +40°C Cl III, Div 1, T4A @ +55°C Cl III, Div 1, T5 @ +40°C File No. E254313 |
ATEX certified Ex II 3G EEx nA nL IIC T2 (Tamb -20 to +55°C) Cert: DEMKO 06 ATEX 0421554 |
Light Source |
24VDC (20-28V) @ 560mA 48VDC (42-58V) @ 260mA 120VAC ±10% 50-60Hz @ 185mA 230VAC ±10% 50-60Hz @ 107mA |
|
Operating Temperature |
Body: UL94V0 & ABS; Mounting bracket: stainless steel; Glass dome: borosilicate; Glass dome guard: stainless steel |
|
Environmental Protection | NEMA TYPE 4 / 4X / 13 | |
Cable Entry | One ½”NPT | Two M20 |
Terminations | 18″ / 0.5m flying leads | Terminals for 0.5 to 2.5mm² wire |
Weight | 3.26lb / 1.48Kg | |
Other | UL Approval includes for end-of-line resistor on DC-powered versions (see instruction manual) | ATEX certification includes for in/out wiring (see instruction manual) |
E2xB10-UL Installation Instructions
E2xB10-UL UL Certificate of Compliance
E2xCS112-5 Specifications | ||||
Available Models | E2xCS112-5-UL | E2xCS112-5-EG | ||
Certification |
UL Approved, US & Canada Cl I, Div 2, Grp A-D T2D @ +55°C Cl I, Div 2, Grp A-D T3 @ +40°C Cl II, Div 2, Grp F&G T6 @ +55°C Cl III, Div 1 T6 @ +55°C File No. E230764 |
ATEX certified Ex II 3G EEx nA nL IIC T2 (Tamb -20 to +55°C) Ex II 3G EEx nA nL IIC T3 (Tamb -20 to +40°C) Cert: DEMKO 06 ATEX 0421554 |
||
Alarm Sound Output | 110 dB(A) @ 1 m ±3dB | |||
Effective Range | 328′ / 100m @ 1kHz | |||
Power Supply Options |
24VDC (10-30V) @ 284mA (sounder), 275mA (beacon) 48VDC (38-58V) @ 146mA (sounder), 145mA (beacon) 120VAC ±10% 50-60Hz @ 104mA (sounder), 80mA (beacon) 230VAC ±10% 50-60Hz @ 54mA (sounder), 30mA (beacon) |
|||
Alarm Sound Modes | 45 alarm tones, (PFEER/UKOOA compliant), 3 stages remotely selectable | |||
Beacon Details |
Xenon, 5 Joule @ 1Hz (5 Ws), user replaceable. Xenon tube mechanically secured against vibration/shock. Lens colors: red, amber/orange, blue, green, yellow, clear. |
|||
Operating Temperature | -4 to +131°F / -20 to +55°C | |||
Materials |
Body: UL94V0 & ABS; Mounting bracket: stainless steel; Glass dome: borosilicate; Glass dome guard: stainless steel |
|||
Environmental Protection | NEMA TYPE 4 / 4X / 13 | IP 66 / IP67 | ||
Cable Entry | One ½”NPT | Two M20 | ||
Terminations | 18″ / 0.5m flying leads | Terminals for 0.5 to 2.5mm² wire | ||
Weight | 6.6lb / 3.0Kg | 7.72lb / 3.5Kg | 6.6lb / 3.0Kg | 7.72lb / 3.5Kg |
Other | UL Approval includes for end-of-line resistor on DC-powered versions (see instruction manual) | ATEX certification includes for in/out wiring (see instruction manual) |
E2xCS112-5-UL Installation Instructions
E2xCS112-5-UL UL Certificate of Compliance
Exloc Instruments, Inc., is a one-stop-shop for instruments and electrical equipment for hazardous and classified locations.
15584 Summit Park, Suite 303
Montgomery, TX 77356
Fill out your contact details and we will forward you to download our product brochures.