IS-MB1 SPECIFICATIONS | |
Certification | Factory Mutual: Cl I, Div 1, Grp A-D; Class I, Zone 0, AEx ia IIC T4 ATEX & IECEx: II 1G EEx ia IIC T4 (-40°C<=Ta<=+60°C) |
Operating Voltage | 16-28VDC via Zener or galvanically isolated safety barrier |
Current Draw | 25mA typical when powered from 24VDC via a safety barrier; beacon has internal current limiting and reverse current protection |
Light Source | Six high intensity LEDs with prismatic lens to optimize LED visibility |
Light Output | Double flash in two configurable modes: 1Hz / 2Hz |
Lens Colors | Red, orange/amber, green, blue, clear |
Dimensions | 3.35″ h x 3.74″ dia* / 85 h x 95 dia* mm. *Inc. lens fastener protrusion |
Operating Temperature | -40 to +140°F / -40 to +60°C |
Environmental | Ingress protection: IP65Housing material: ABS flame retardant; Lens: polycarbonate.Relative humidity: 90% max. @ 120°F / 50°C |
Cable Entry | 2x M20 knockouts |
Other | End-of-line (EOL) resistor certified for fire & gas alarm systems |
[vc_accordion][vc_accordion_tab title=”IS-MB1 Beacon, Barrier Recommendations” open=”0″]
The IS-MB1 Beacon requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=660mA, Po/Po=1.2W.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “A” terminals in each case.
Suitable barrier: GMI D1042Q (quad channel) with each output separately powering an individual IS-MB1 beacon.
Note that while each beacon has it’s own dedicated barrier channel, a complete failure of the barrier module will affect all alarm notifications associated with it.
IS-MB1 SPECIFICATIONS | |
Certification | Factory Mutual: Cl I, Div 1, Grp A-D; Class I, Zone 0, AEx ia IIC T4 ATEX & IECEx: II 1G EEx ia IIC T4 (-40°C<=Ta<=+60°C) |
Operating Voltage | 16-28VDC via Zener or galvanically isolated safety barrier |
Current Draw | 25mA each typical for beacon and sounder powered separately from 24VDC via safety barriers, 30mA total typical when beacon and sounder are powered from a common barrier; unit has internal current limiting and reverse current protection |
Light Source | Six high intensity LEDs with prismatic lens to optimize LED visibility |
Light Output | Double flash in two configurable modes: 1Hz / 2Hz |
Lens Colors | Red, orange/amber, green, blue, clear |
Alarm Sound Output | 100 dB(A) @ 1 m; effective range up to 130′ / 40 m @ 1kHZ Sample Alarm Tones |
Alarm Sound Modes | 49 configurable tone combinations, 3 stages (PFEER/UKOOA compliant) |
Dimensions | 4.60″ h x 3.74″ dia* / 116 h x 95 dia* mm. *Inc. lens fastener protrusion |
Operating Temperature | -40 to +140°F / -40 to +60°C |
Environmental | Ingress protection: IP65Housing material: ABS flame retardant; Lens: polycarbonate.Relative humidity: 90% max. @ 120°F / 50°C |
Cable Entry | 2x M20 knockouts |
Other | End-of-line (EOL) resistor certified for fire & gas alarm systems |
The IS-MC1 Combination Beacon & Sounder may be powered from a single intrinsic safety barrier providing 16VDC @ 35mA and with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barriers: P&F KFDO-SD2-Ex1.1045; MTL5025
Note that failure of the single barrier will negate both alarm notification modes.
The beacon requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=660mA, Po/Po=1.2W.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “A” terminals in each case.
The sounder requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “C” terminals in each case.
Note that the failure of one barrier will leave the other alarm notification mode working.
Suitable barrier: GMI D1042Q (quad channel) with each output separately powering either a beacon or a sounder. Under no circumstances may two barrier channel outputs be connected in parallel to power one beacon-sounder combination.
Note that while each beacon and sounder has it’s own dedicated barrier channel, a complete failure of the barrier module will negate all alarm notifications associated with it.
Sounder Stage 2 Control (only): D1044S (single channel)
Sounder Stage 2 & 3 Control: D1044D (dual channel, one channel used per control line)
IS-MB1 SPECIFICATIONS | |
Certification | Factory Mutual: Cl I, Div 1, Grp A-D; Class I, Zone 0, AEx ia IIC T4 ATEX & IECEx: II 1G EEx ia IIC T4 (-40°C<=Ta<=+60°C) |
Operating Voltage | 16-28VDC via Zener or galvanically isolated safety barrier |
Current Draw | 25mA each typical for beacon and sounder powered separately from 24VDC via safety barriers, 30mA total typical when beacon and sounder are powered from a common barrier; unit has internal current limiting and reverse current protection |
Light Source | Six high intensity LEDs with prismatic lens to optimize LED visibility |
Light Output | Double flash in two configurable modes: 1Hz / 2Hz |
Lens Colors | Red, orange/amber, green, blue, clear |
Alarm Sound Output | 100 dB(A) @ 1 m; effective range up to 130′ / 40 m @ 1kHZ Sample Alarm Tones |
Alarm Sound Modes | 49 configurable tone combinations, 3 stages (PFEER/UKOOA compliant) |
Dimensions | 4.60″ h x 3.74″ dia* / 116 h x 95 dia* mm. *Inc. lens fastener protrusion |
Operating Temperature | -40 to +140°F / -40 to +60°C |
Environmental | Ingress protection: IP65Housing material: ABS flame retardant; Lens: polycarbonate.Relative humidity: 90% max. @ 120°F / 50°C |
Cable Entry | 2x M20 knockouts |
Other | End-of-line (EOL) resistor certified for fire & gas alarm systems |
The IS-MC1 Combination Beacon & Sounder may be powered from a single intrinsic safety barrier providing 16VDC @ 35mA and with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barriers: P&F KFDO-SD2-Ex1.1045; MTL5025
Note that failure of the single barrier will negate both alarm notification modes.
The beacon requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=660mA, Po/Po=1.2W.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “A” terminals in each case.
The sounder requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “C” terminals in each case.
Note that the failure of one barrier will leave the other alarm notification mode working.
Suitable barrier: GMI D1042Q (quad channel) with each output separately powering either a beacon or a sounder. Under no circumstances may two barrier channel outputs be connected in parallel to power one beacon-sounder combination.
Note that while each beacon and sounder has it’s own dedicated barrier channel, a complete failure of the barrier module will negate all alarm notifications associated with it.
Sounder Stage 2 Control (only): D1044S (single channel)
Sounder Stage 2 & 3 Control: D1044D (dual channel, one channel used per control line)
The BA386 provides a bright flashing warning signal in a plant or processing area where ambient noise levels may drown out an audible alarm. It is significantly less expensive than traditional Xenon devices, yet has a similar light output and flashes more rapidly – making it more immediately noticable. Available in five colors to enable multi-stage alarm level protocols. Factory Mutual and ATEX intrinsic safety certification enable it to be used in virtually any classified hazardous location.
Can be used in conjunction with a BR385 alarm sounder using a single galvanically isolated barrier. The BA386 beacon includes terminals to power the sounder, and for an external push button to silence the sounder. The silence time is adjustable from 1 to 30 minutes. We can even supply a kit to combine the two units.
BA386 BEACON & BR385 SOUNDER COMBINATION,
BARRIER RECOMMENDATIONS
Option 1 – mutual two-wire connection:
The BA386 Beacon & BR385 Sounder Combination may be powered from a single intrinsic safety barrier providing 16VDC @ 35mA and with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barriers: P&F KFDO-SD2-Ex1.1045; MTL5025
Note that failure of the single barrier will negate both alarm notification modes.
Option 2 – high integrity four-wire connection, beacon and sounder powered separately:
The BA386 Beacon requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=110mA, Po/Po=800mW.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “B” terminals in each case.
The BR385 Sounder requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “C” terminals in each case.
Note that the failure of one barrier will leave the other alarm notification mode working.
Option 3 – multiple beacon & sounder combos, use of multi-channel barrier for economy:
Suitable barrier: GMI D1042Q (quad channel) with each output separately powering either a beacon or a sounder. Under no circumstances may two barrier channel outputs be connected in parallel to power one beacon-sounder combination.
Note that while each beacon and sounder has it’s own dedicated barrier channel, a complete failure of the barrier module will negate all alarm notifications associated with it.
BA386 BEACON & BR385 SOUNDER COMBINATION,
BARRIER RECOMMENDATIONS
Option 1 – mutual two-wire connection:
The BA386 Beacon & BR385 Sounder Combination may be powered from a single intrinsic safety barrier providing 16VDC @ 35mA and with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barriers: P&F KFDO-SD2-Ex1.1045; MTL5025
Note that failure of the single barrier will negate both alarm notification modes.
Option 2 – high integrity four-wire connection, beacon and sounder powered separately:
The BA386 Beacon requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=110mA, Po/Po=800mW.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “B” terminals in each case.
The BR385 Sounder requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “C” terminals in each case.
Note that the failure of one barrier will leave the other alarm notification mode working.
Option 3 – multiple beacon & sounder combos, use of multi-channel barrier for economy:
Suitable barrier: GMI D1042Q (quad channel) with each output separately powering either a beacon or a sounder. Under no circumstances may two barrier channel outputs be connected in parallel to power one beacon-sounder combination.
Note that while each beacon and sounder has it’s own dedicated barrier channel, a complete failure of the barrier module will negate all alarm notifications associated with it.
DA135 beacons offer multiple alarm modes to provide visual warnings in a variety of situations. A choice of five bright colors – including blue and white – plus single, dual and triple flash cycles. There’s even a dual color option to warn operators of a relative change in status. Protective lenses appear clear until the LEDs are illuminated. Each beacon may be connected to a sounder and acknowledge/reset pushbutton to create a local alarm station. The electronics are totally encapsulated, and wiring connections are made in a separate terminal chamber. All control connections are fully isolated to simplify circuit design.
Option 1 – single beacon installation:
The DA135 Beacon requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=110mA, Po/Po=800mW.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “B” terminals in each case.
Option 2 – multiple beacons, use of multi-channel barrier for economy:
Suitable barrier: GMI D1042Q (quad channel) with each output separately powering an individual BA386 beacon.
Note that while each beacon has it’s own dedicated barrier channel, a complete failure of the barrier module will affect all alarm notifications associated with it.
Option 1 – mutual two-wire connection:
The DA135 Beacon & BR385 Sounder Combination may be powered from a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barriers: P&F KFDO-SD2-Ex1.1045; MTL5025
Note that failure of the single barrier will negate both alarm notification modes.
Option 2 – high integrity four-wire connection, beacon and sounder powered separately:
The DA135 Beacon requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=110mA, Po/Po=800mW.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “B” terminals in each case.
The BR385 Sounder requires a single intrinsic safety barrier with safety/entity parameters not exceeding the following values:
Uo/Voc=28V, Io/Isc=93mA, Po/Po=660mW.
Suitable barrier: GMI D1048S / D1049S / D5048S / D5049S using output “C” terminals in each case.
Note that the failure of one barrier will leave the other alarm notification mode working.
Option 3 – multiple beacon & sounder combos, use of multi-channel barrier for economy:
Suitable barrier: GMI D1042Q (quad channel) with each output separately powering either a beacon or a sounder. Under no circumstances may two barrier channel outputs be connected in parallel to power one beacon-sounder combination.
Note that while each beacon and sounder has it’s own dedicated barrier channel, a complete failure of the barrier module will negate all alarm notifications associated with it.
Exloc Instruments, Inc., is a one-stop-shop for instruments and electrical equipment for hazardous and classified locations.
15584 Summit Park, Suite 303
Montgomery, TX 77356
Fill out your contact details and we will forward you to download our product brochures.