Intrinsically Safe Panel Mounting |
Model |
BA377E |
BA378E |
BA377E-SS |
Image |
|
|
|
Mouting Type |
Panel |
Panel |
Rugged Panel |
Enclosure |
96 x 48 mm |
144 x 72 mm |
105 x 60 mm |
Separate terminal
compartment |
N/A |
N/A |
N/A |
Case material |
Noryl |
316 Stainless Steel |
Protection |
Front IP66, rear IP20 |
Display |
8 digits 9mm high
6 digits 6mm high |
8 digits 18mm high
6 digits 12mm high |
8 digits 9mm high
6 digits 6mm high |
No. of inputs |
1 |
2 |
1 |
Certification |
|
|
|
Europe
ATEX |
Group II Category 1G
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C |
Group II Category 1GD
Ex ia IIC T5 Ga
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C |
USA & Canada
ETL & cETL
Intrinsic safety |
Class I Div 1 Gp A, B, C, D T5 (USA & Canada)
Class II Div 1 Gp E, F, G. Class III Div 1 (USA & Canada)
Class I Zone 0 AEx ia IIC T5 Ga (USA)
Ex ia IIC T5 Ga (Canada)
-40°C ≤ Ta ≤ 70°C |
|
|
|
Zone 20 AEx ia IIIC
T80°C Da (USA)
Ex ia IIIC T80°C Da
(Canada)
-40°C ≤ Ta ≤ 60°C
May be installed in an
AEx e, AEx p, AEx n
or AEx t panel
enclosure without
invalidating enclosure
certification. |
USA & Canada
ETL & cETL
Nonincendive |
Class I Div 2 Gp A, B, C, D T5 (USA & Canada)
Class II Div 2 Gp F, G. Class III Div 2 (USA & Canada)
-40°C ≤ Ta ≤ 70°C |
International
IECEx |
Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C |
Ex ia IIC T5 Ga
Ex ia IIIC T80°C Da
-40°C ≤ Ta ≤ +60°C |
Optional |
|
|
|
Backlight |
Yes |
Control outputs |
Yes |
Status output |
Not available |
Standard |
Not available |