Explosion Proof Loudspeakers with Flare Horn

EXPLOSION PROOF LOUDSPEAKERS WITH FLARE HORN

D1XL1F PA LOUDSPEAKER 15W

The D1xL1F is a 15W PA loudspeaker with re-entrant flare horn. A high SPL in a robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosure ensures the D1xL1F is suitable for all Class I & II Division 1 & Zone 1 & 20 explosion proof applications.

The re-entrant flare horn is high impact, fire retardant ABS and is field replaceable – the driver employs a standard 1 3/8″ -18 male thread coupling. All models have triple cable entries, and large termination areas. The termination chamber and cover feature a threaded flameproof joint simplifying both installation and routine maintenance.

D1xL1F PA Loudspeaker 15W
Specifications
SPL (Gas Version) 102dB +/-3dB @ 1W @1m (Pink)
133dB +/-3dB @ 15W @ 1 m (Rated
SPL (Dust Version) 83dB +/-3dB @ 1W @1m (Pink
95dB +/-3dB @ 15W @ 1m (rated
Rated Power: 15 Watts RMS
70v Line Tappings 15W/7.5W/3W/1W
(z=336.67 Ohms/653.33 Ohms/106k Ohms/4.9k Ohms)
Low Impedance 8 Ohm or 16 Ohm
Directivity Index: 6.2 @ 1kHz & 16.0 @ 4kHz [dB on-axis]
Frequency Range: 400Hz to 8000 Hz
DC Line Monitoring 2.2µF Capacitor (Transformer )
470µF Capacitor (Low impedance)
Ingress Protection: EN60529:IP66
UL50E/NEMA250: 4/4X/3R/13
Enclosure Material: Marine grade aluminium LM6-copper free
Chromated & Powder coated- corrosion proof
Color Red (RAL3000), Grey (RAL 7038)
Cable Entries: 1 x 1/2″NPT & 2 x M20 x 1.5mm
1 x 1/2″NPT & 2 x 1/2″NPT
1 x 1/2″NPT & 2 x 3/4″NPT
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Grounding Stud: M5
Operating temp: -40° to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight 70V line: 4.3kg/9.5Ibs
Storage temp: (-40 C to +70 C -40 to +158F): Low imp.: 4.0kg/8.7Ib
Hazardous Area A1:Gas version
NEC/CEC
Class I Div I ABCD T6 Ta -40C to +70C
Class I Div 2 ABCD T6 Ta -40C to +70C
Class I Zone 1, 2 IIC T6 Ta -40C to + 70C
D1: Dust Version
NEC/CEC
Class II Div 1 FG T6 Ta -40C to +70C
Class II Div 2 FG T6 Ta -40C to +70C
Class III Div 1 & 2
Zone 20, 21, 22 IIB Ta -40C to +70C

Datasheet

Range Brochure

Class 1 Gas Installation Manual

Class II Dust Installation Manual

Declaration of Conformity

Get Help/Quote

D1XL2F PA LOUDSPEAKERS 25W

The D1xL2F is a 25W PA loudspeaker with re-entrant flare horn. A high SPL in a robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosure ensures the D1xL2F is suitable for all Class I & II Division 1 & Zone 1 & 20 explosion proof applications.

The re-entrant flare horn is high impact, fire retardant ABS and is field replaceable – the driver employs a standard 1 3/8″ -18 male thread coupling. All models have triple cable entries, and large termination areas. The termination chamber and cover feature a threaded flameproof joint simplifying both installation and routine maintenance.

D1xL2F PA Loudspeaker 15W
Specifications
SPL (Gas Version) 104dB +/-3dB @ 1W @1m (Pink)
118dB +/-3dB @ 15W @ 1 m (Rated
SPL (Dust Version) 83dB +/-3dB @ 1W @1m (Pink
97dB +/-3dB @ 15W @ 1m (rated
Rated Power: 25 Watts RMS
70v Line Tappings 25W/12.5W/6W/2W tappings
(z=196 Ohms/392Ohms/816.67 Ohms/2.45k Ohms)
Low Impedance 8 Ohm or 16 Ohm
Directivity Index: 7.6 @ 1kHz & 17.6 @ 4kHz [dB on-axis]
Frequency Range: 300Hz to 8000 Hz
DC Line Monitoring 2.2µF Capacitor (Transformer )
470µF Capacitor (Low impedance)
Ingress Protection: EN60529:IP66
UL50E/NEMA250: 4/4X/3R/13
Enclosure Material: Marine grade aluminium LM6-copper free
Chromated & Powder coated- corrosion proof
Color Red (RAL3000), Grey (RAL 7038)
Cable Entries: 1 x 1/2″NPT & 2 x M20 x 1.5mm
1 x 1/2″NPT & 2 x 1/2″NPT
1 x 1/2″NPT & 2 x 3/4″NPT
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Grounding Stud: M5
Operating temp: -40° to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight 70V line: 4.3kg/9.5Ibs
Storage temp: (-40 C to +70 C -40 to +158F): Low imp.: 4.0kg/8.7Ib
Hazardous Area A1:Gas version
NEC/CEC
Class I Div I ABCD T6 Ta -40C to +70C
Class I Div 2 ABCD T6 Ta -40C to +70C
Class I Zone 1, 2 IIC T6 Ta -40C to + 70C
D1: Dust Version
NEC/CEC
Class II Div 1 FG T6 Ta -40C to +70C
Class II Div 2 FG T6 Ta -40C to +70C
Class III Div 1 & 2
Zone 20, 21, 22 IIB Ta -40C to +70C

Datasheet

Range Brochure

Class 1 Gas Installation Manual

Class II Dust Installation Manual

Declaration of Conformity

Get Help/Quote

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT

Download Product and Service Catalogs

Fill out your contact details and we will forward you to download our product brochures. 

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT