D1XC2X05F ALARM HORN & XENON STROBE

125dB(A) horn & 5 Joule Xenon. The D1xC2X05F is a high output alarm horn sounder with re-entrant flare horn combined with a 500,000cd Xenon strobe beacon. The robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosure ensures the D1xC2X05F is suitable for all Class 1 & 2 Division 1, Zone 1 & 20 explosion proof signaling applications. The DC version is approved for public mode fire alarm use (alarm horn) and private mode fire alarm use (strobe beacon).

The alarm horn & Xenon strobe may be powered from a common or dual supply allowing simultaneous or independent operation. Featuring 64 first stage/channel alarm sounds, the alarm tone frequencies for the first 2 stages are independently selectable. Each of the available 4 stage/channels can be remotely triggered e.g. via an external relay.

D1xC2X05F Alarm Horn and Strobe for Signaling
Specifications
Alarm Horn
Maximum Output 125dB (A) @ 1 meter [116dB(A) @ 10ft/3m]
Nominal Output 120dB (A) @ 1m+/-3dB-Tone 35 [112dB (A) @ 10ft/3m]
No. of Tones 64 (UKOOA/PFEER compliant)
No. of Stages 4
Volume Control Adjustable -12dB (A)
Effective Range 200m/656ft @ 1KHz
Supply Voltages 24Vdc; 115Vac; 230Vac
Stage Switching DC units: negative or positive
AC units:common supply line
Strobe Beacon
Energy 5 Joules (5Ws)
Flash Rates Option 1: 1Hz (60 fpm)
Option 2: 1.5Hz (90fpm)
Option 3: Double Strike
Peak Candela 500,000 cd-calculated from energy (J)
Effective Intensity 250 cd- calculated from energy (J)
Peak Candela 46,976 cd*- measured ref. to I.E.S.
Effective Intensity 143 cd*-measured ref. to I.E.S.
Lens Colors Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube Life: Emissions are reduced to 70% after 8 million flashes
Hazardous Area Rating A1: Gas version NEC / CEC:
Class I Div 1 ABCD T5/T6 Ta -40°C to +70/+55°C
Class I Div 2 ABCD T5/T6 Ta -40C to +55/+50C
Class I Zone 1, 2 IIC T5/T6 Ta -40C to +55/+50C
D1: Dust version
NEC/CEC
Class II Div 1 FG T4/T4A Ta -40C to +55/+40C
Class II Dvi 2 T4/T4A Ta -40C to +55/+40C
Class III Div 1 & 2
Zone 20, 21, 22 IIIB T4/T4A Ta -40C to +55/=40C

Datasheet

Range Brochure

Class 1 Gas Installation Manual

Class II Dust Installation Manual

Declaration of Conformity

Get Help/Quotation

D1XC2X10F ALARM HORN & XENON STROBE

125dB(A) horn & 10 Joule Xenon. The D1xC2X10F is a high output alarm horn sounder with re-entrant flare horn combined with a 1,000,000cd
Xenon strobe beacon. The robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosure ensures the D1xC2X10F is suitable for all Class 1 Division 1 & Zone 1 explosion proof signaling applications. The DC version is approved for public mode fire alarm use (alarm horn) and private mode fire alarm use (strobe beacon).

The alarm horn & Xenon strobe may be powered from a common or dual supply allowing simultaneous or independent operation. Featuring 64 first stage/channel alarm sounds, the alarm tone frequencies for the first 2 stages are independently selectable. Each of the available 4 stage/channels can be remotely triggered e.g. via an external relay.

D1xC1X05F Alarm Horn & Xenon Strobe
Specifications
Flare Re-Entrant Horn
Maximum Output 117dB (A) @ 1 meter [108dB(A) @ 10ft/3m]
Nominal Output 113dB (A) @ 1m+/-3dB-Tone 2 [104dB (A) @ 10ft/3m]
No. of Tones 64 (UKOOA/PFEER compliant)
No. of Stages 4
Volume Control Adjustable -12dB (A)
Effective Range 125m/410ft @ 1KHz
Supply Voltages 24Vdc; 115Vac; 230Vac
Stage Switching DC units: negative or positive
AC units:common supply line
Strobe Beacon
Energy 5 Joules (5Ws)
Flash Rates Option 1: 1Hz (60 fpm)
Option 2: 1.5Hz (90fpm)
Option 3: Double Strike
Peak Candela 500,000 cd-calculated from energy (J)
Effective Intensity 250 cd- calculated from energy (J)
Peak Candela 46,976 cd*- measured ref. to I.E.S.
Effective Intensity 143 cd*-measured ref. to I.E.S.
Lens Colors Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube Life: Emissions are reduced to 70% after 8 million flashes
Hazardous Area Rating A1: Gas Version
NEC / CEC:
Class I Div 1 ABCD T5/T6 Ta -40°C to +70/+55°C
Class I Zone 1, 2 IIC T5/T6 Ta -40°C to +70/+55°C
D1: Dust Version
NEC / CEC:
Class II Div 1 FG T4/T4A Ta -40°C to +55/+40°C
Class III Div 1&2
Zone 20, 21, 22 IIIB T4/T4A Ta -40°C to +55/+40°C

Datasheet

Range Brochure

Class 1 Gas Installation Manual

Declaration of Conformity

Get Help/Quotation

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT

Download Product and Service Catalogs

Fill out your contact details and we will forward you to download our product brochures. 

HAZARDOUS AREA INSTRUMENTS
BACKED WITH INDUSTRY LEADING SERVICE AND SUPPORT